View and Download Aritech Advisor CD72 installation manual. Related Manuals for Aritech. CD 9031 315 x 385 x 88 (1,25 mm steel plate) CD 72/95 475 x. View Online - Installation Manual CD72/95/150. ARITECH KD3000 S Installation Manual ARITECH CD7202S3 Installation Manual EN ARITECH ARITECH CD 72 (CD72).
The simple design of the Folding Manual Treadmill lets you use it in small space, then easily tilt and roll it out of the way when finished. Just unfold and start walking. Go as fast as you like.the treadmill keeps pace with you. An easy-to-read LCD screen shows duration, speed, distance, and calories burned. Cushioned handlebars provide a comfortable grip.
- Monitor shows Time, Speed, Distance, Calorie and Scan - Folds for easy storage - Supports up to 220 lbs. Usda Ams Process Verified Program Comcast. - Includes 2 AA batteries - Non-slip running surface - Open dimensions: 49'L x 23'W x 50'H - Assembly.
The 'Programming Manual’ is available from your ARITECH national office. The ‘Programming Map’ for the various systems can be found at the end of this manual. • Page 4 Installation manual for CD2. 7 NSTALLATION GUIDELINES Before switching on the power... Separate alarm and tamper connection.. Joint Connecting the alarm & tamper..8 Figure 3. Overview of the dipswitches on remotes..
9...11 ROGRAMMING GUIDE Figure 4. • Connecting a fire detector...25 Figure 20. Connecting a fire detector..25 Outputs.... 26 Connecting a relay or an LED...26 Figure 21. Connecting a relay or an LED on the output.. 26 Connecting an AS256 and AS294/394 sounder.. 27 Figure 22.
• NSTALLATION GUIDELINES The CD72, CD95/150 control panels have been designed, assembled and tested to meet current standards of stability and resistance to electrical interference from the environment. If the following guidelines are followed, the system should give many years of reliable service. Ensure that there is a good earth for the alarm system.
• EFORE SWITCHING ON THE POWER Detectors (or key switches) can be connected in two ways: Conventional: One zone each is required for both tamper and the alarm. Both zones should be closed with an end-loop resistor (4.7 kOhm). Program the ‘zones’ menu as ‘Alarm’ Figure 1. • Set the DIP switches of all the remote keypads and expanders. Remote 1 must be a keypad. CD72, remotes 2 to 4 must be keypads and remotes 5 and 6 expanders. CD95/150, remotes 2 to 8 can be keypads or expanders but remotes 9 to 16 must be expanders.
Keypad 1 Remote 2 Remote 3. • Supply only mains power to the control panel. The system will power up in the ARMED state. Any zones that may be open will initiate a full alarm condition and the sounders will activate.
Do not use a battery to power the system when installing or changing the installation. If there is a short circuit in the 12 volt power supply, the voltage regulators in the supply (together with the fuses) will prevent serious damage to the system The 12 volt power supply will decrease sharply in the event of a short circuit. • ROGRAMMING GUIDE Take some time to become familiar with the overview of the programming maps which can be found at the end of this manual. Any programming changes made may not take effect until you exit programming mode. If while programming an option the message “No Privilege” is displayed, the configuration is “Split System”. • ETURNING TO DEFAULT SETTINGS There are two methods of returning the system (not the dialler) to default settings, these are: The removal of JP1 (CD72) or LK1 (CD95/150).