• MISERMATIC BATTERY IGNITION RADIANT CONVECTOR GAS FIRE Installation, Maintenance & User Instructions Hand these instructions to the user Model No’s FORM**EN are for use on Natural Gas (G20) at a supply pressure of 20 mbar in G.B. ** denotes colour variance. • CONTENTS Page Section 1 Appliance Data Conditions of Installation. Flue & Chimney Suitability Fireplace/Surround Suitability Shelf Position Side Clearance Closure Plate Flue & Chimney inspection Chimney Catchment space 1.8.1 Brick Built Chimney 1.8.2 Fitting to Pre-Fab.
Appliance manuals and free pdf instructions. Find the user manual you need for your home appliance products and more at ManualsOnline. Cannon Gas Miser Manual Transmission. 7/14/2017 0 Comments. 700: aerator, lawn $ air conditioner: 15: 2360: 1 ton 115v portable a/c unit $ air conditioner.
Twin Wall Metal Flueboxes 1.8.3 Fitting to Pre-Cast Flue Installations Hearth Fitting. • APPLIANCE DATA Main injector (1 off) Stereomatic Elbow size 76 Pilot Type. Copreci Single Flame 21100 / 161 Max. Gross Heat Input: 6.9 kW Min. Gross Heat Input: 2.5 kW Cold Pressure: 20.0 +/- 1.0 mbar (8.0 +/- 0.4 in w.g.) Ignition: Battery Ignition, 1.5V Electrode Spark Gap. • CONDITIONS OF INSTALLATION In Great Britain:- It is law that all gas appliances are installed only by a registered installer in accordance with these installation instructions and the Gas Safety (Installation and use) Regulations 1998. Failure to install appliances correctly could lead to prosecution.
• FIREPLACE / SURROUND SUITABILITY The fire is suitable for hearth mounting or wall mounting. It must not be fitted directly onto a carpet or other combustible material. It must not be fitted to combustible walls. This fire is suitable for the following hearth / surround types: Non-combustible hearths / surrounds. • Brick / stone built chimneys and any chimney or flue which has been used for an appliance burning fuel other than gas must be thoroughly swept.
The base of the chimney/flue must also be thoroughly cleared of debris etc. Any under floor air supply to the fireplace must be completely sealed off. Ensure that the inside of the chimney/flue is in good condition along its length and check that there is no leakage of smoke through the structure of the chimney during and after the smoke pellet test. • The front opening of the fireplace must be between 305mm and 440mm wide, and between 580mm and 650mm high. If the opening is larger than this, then a surround must be constructed in a suitable non-com bustible material to create an opening to these limits. Allow a minimum flat surface of 10mm around the opening to ensure that the closure plate can be sealed to the fireplace. Bruce Jewell Business Studies Pdf Converter. • This appliance has been tested for use in a pre-cast flue block complying with BS EN 1858.
In accordance with BS EN 1858, pre-cast flues built with directly plastered faces (front or rear) are not correctly installed as to ensure proper operation with any type of gas fire. • PACKING CHECK LIST 1 off Firebox / Burner Assembly 1 off Flue Spigot 1 off Closure Plate 1 off Literature / Loose Items Pack 1 off Pack of Screws & Fixings for Wall Mounting 4 off Ceramic Radiants – Packed inside firebox 1 off AA Battery 1 off Arthritic control knob and 2 off self adhesive pads INSTALLATION OF FIRE. 3 To Remove the Lower Outer Case Fixing Screws Fig. 4 Remove the Upper Outer Case Fixing Screws Remove the flue spigot restrictor if the fire if the fire is the to be fitted to a pre cast flue. The flue spigot restrictor is attached to the fire back with two screws. • CLOSURE PLATE.
Fit the closure plate to the fireplace opening and ensure that it has a flat sealing area of at least 10mm sealed on all sides. 5 below Dimensions stated are for closure plate supplied Fireplace Opening 460mm Fig. • WALL MOUNTING. (NON COMBUSTIBLE WALLS ONLY) NOTE: When the fire is wall mounted, the base of the fire must be a least 150mm above the floor level.